Ports

Board 2

Connect the GGM IDS

The default setting for the induction hob is:

Type
Color
Connection

Interrupt

blue/green

- (unoccupied) or D5

Command

yellow

D6

Relay

white

D7

Voltage +

red

5V/Vcc

Tension -

black

GND

On the wiring diagram, the 5 connections for the induction hob are marked "GGM". The GGM connection cable from the control panel has a blue cable, while the replacement cable has a green cable.

The Brautomat including the display can be operated with the power supply of the GGM IDS. All you have to do is plug the red and black cables into the marked screw terminals. In this case, another additional power supply must not be connected to the ESP microcontroller.

Alternatively, the Brautomat can be operated with a 5V DC power supply. In this case the red cable is not connected to the GGM IDS.

Connect Dallas DS18B20 temperature sensors

The Brautomat supports up to three DS18B20 temperature sensors. The connector is marked DS18B20-1 to DS18B20-3 on the board illustration. The colors of the sensor cables are different. For very cheap sensors without labeling or description, the color scheme is usually black - red - yellow.

Type
Color
Connection

Voltage +

green or red

Vcc

Data line

white or yellow

Data

Tension -

brown or black

GND

There is no order of connections for the Dallas DS18B20 digital sensors.

Connect temperature sensors PT100x and MAX31865.

Type
Connection

SPI clock in

SCLK D9

SDO MasterIn SlaveOut

MISO D10

SDI MasterOut SlaveIn

MOSI D11

Chip select pin 0

CS0 D13

Chip select pin 1

CS1 D16

Chip select pin 2

CS2 D17

Vin

3V3

GND

GND

The sequence CS0 to CS2 for connecting PT100x sensors must be observed.

Connect display

Cable
Nextion Display
Connection

red

Current +

Vcc

black

Electricity -

GND

blue

TX

D1

yellow

RX

D2

Last updated